• A square cut shall be made on the pipe using a mitre box and fine-toothed panel saw.
  Remove all burrs and swarf. Slightly chamfer the external pipe edge.

• Clean the pipe and matching sockets using premier fluid.

• Keep the cleaned surfaces free or dirt and grease.

• Apply an even coat of approved PVC solvent cement by using a clean brush to outside of the spigot pipe and the inside of the socket.

• While the surface still wet, push the pipe (spigot end) straight into the socket until the full depth of the socket reached with a slight twisting motion. Hold for 20 –    30 seconds without movement.

• Remove any surplus cement from the mouth of the socket with a soft cloth. The pipe may be handled, but not unduly strained for 1 hour. Wait 4 hours before putting    to use.

finalsolvent1

Product Code:- SSCPVC500-T

Solid content : 24%
Consistency property : 1,000 cps
Quality : Tough & Resilent

finalsolvent2

Product Code:- SSCPVC500-G

Solid consists of : MEK & CYC
Colour : Transparent / Green
Standard : MS628 Part II Section 2.2

• A highly soluble fast-dry UPVC solvent cement
• When applied, it will instantly dissolve and blend with the pipe to produce
• a film (wall) of 0.4mm thick, so that the fitting gap will be strong and stable

RECOMMENDATIONS ON BRUSH:-
A : Pipes with diameter 25mm (1”) and below - use brush as accompanied and affixed to can.
B : Pipes with diameter 32mm to 50mm (11/4” to 2”) - use separate 1” brush
C : Pipes with diameter 75mm to 200mm (3” to 8” and above) -use separate 2” brush

PRESSURE TEST:-

Cold Water (20°C)
Hot Water (60°C)

TEST PRESSURE

Below 12kg/cm²(171psi)
Below 12kg/cm²(171psi)

DRYING TIME

After 1 hour
After 2 hour

ESTIMATED SOLVENT CEMENT REQUIREMENT:-











NORMINAL/SIZESNumber Of Possible Joints 500g
(IN.)(MM)
1/215383
3/420250
125200
11/432156
11/240100
25069










NORMINAL/SIZESNumber Of Possible Joints 500g
(IN.)(MM)
38041
410032
615519
820010
102506
123004