The Soil,Waste and Vent(SWV) uPVC Pipes are used for Sanitary Stack.
These pipes are also suitables as rain water downpipes ad other discharge purpose.
Available in white colour, the sizes range is 82mm, 110mm and 160mm diameter .

Dimensions For Soil,Waste and Vent(SWV) Pipes
Normal Size Outside Diameter Wall Thickness
Size Min Max Min Max
(Inches) (mm) (mm) (mm)
3 82 82.40 82.80 3.2 min
4 110 110.00 110.40 3.2 min
6 160 160.00 160.60 3.2 min

The internal and external surfaces of the pipes must be clean,smooth and from grooving and other defects. Joints by solvent cement welding, these pipes are used for above ground installation.

SOIL, WASTE & VENTILATING PIPE (MS 978 ; 1985) BS 5255 : 1983
Normal Size Outside Diameter Wall Thickness
Size Min Max Min Max
(Inches) (mm) (mm) (mm)
32 36.15 36.45 1.80 2.20
40 42.75 43.05 1.90 2.30
2 50 55.75 56.05 2.00 2.40

RAIN WATER DOWN PIPE

BS4576: Part 1: 1989.
Specification for Unplasticized polyvinyl chloride (PVC-U) rain water good and accessories

CS Rainwater down pipe are design mainly for rain and storm water discharge from the roof top or ground.with architect and engineer requirement, we are manufacturer and certified according to international standard.

CS Rainwater down pipe are made from high quality of uPVC material which have excellent properties such as high strength and corrosion resistant with light weight

Consist three type of CS rainwater down pipe:

Light Duty CS pipe is designed for landed properties.such as terrace houses or bunglow.

Medium Duty CS pipe is designed for high rise properties such as apartment, condominium and commercial building.

Heavy Duty CS pipe is designed for higher stiffness especially cast into reinforced concrete columns or pillar.

DIMENSION FOR WATER PRESSURE PIPE (MS 628 : Part 1 : 199 )
Normal Size (mm) Conformace std. Outside Diameter (mm) Thickness (mm) Type Length (Meter)
82 mm BS4576:pt 1:1989 82.4 – 82.8 1.8 – 2.3 LD 4/6
82 mm MS1063:2002 82.4 – 82.8 3.0 – 3.5 MD 4/6
110 mm BS4576:pt 1:1989 110.0 – 110.4 2.2 – 2.7 LD 4/6
110 mm MS1063:2002 110.0 – 110.3 3.2 – 3.8 MD 4/6
110 mm DIN 8061 110.0 – 110.4 6.0 – 6.8 HD 4/6
160 mm MS1063:2002 160.0 – 160.4 4.0 – 4.6 MD 6
160 mm DIN 8061 160.0 – 160.4 8.7 – 9.7 HD 6
200 mm MS1063:2002 200.0 – 200.5 4.9 – 5.6 MD 6
200 mm DIN 8061 200.0 – 200.6 10.8 – 12.0 HD 6
250 mm MS1063:2002 250.0 – 250.5 6.2 – 7.1 MD 6
315 mm MS1063:2002 315.0 – 315.6 7.7 – 8.7 MD 6

The Soil,Waste and Vent(SWV) uPVC Pipes are used for Sanitary Stack.
These pipes are also suitables as rain water downpipes ad other discharge purpose.
Available in white colour, the sizes range is 36mm to 160mm diameter
Equavalent to BS 5255,BS 4514 & BS 5481.
Meyhod of Joint solvent cement & rubbering.
.

 

Dimensions For Soil,Waste and Vent(SWV) Pipes
NominalOutside DiameterWall Thickness
(Application Area)
(B)
(Application Area)
(BD)
SizeMinMaxMinMaxMinMax
(inches)(mm)(mm)(mm)(mm)
11¼3636.2036.503.03.5--
4342.8043.103.03.5--
25655.8056.103.03.5--
38282.4082.803.03.53.03.5
4110110.00110.303.23.83.23.8
6160160.00160.403.23.84.04.6
8200200.00200.503.94.54.95.6
10250250.00250.504.95.66.27.1
12315315.00315.606.27.17.78.7

 

Application Area Code:

Code 'B'=Application for components intended use above ground inside or outside buildings fixed the wall
code 'BD'=Application for components intended use above ground inside or outside buildings fixed the wall and burred in building and structures